Getting Started
DataDirect Networks EF2800 FC RAID Storage System User Guide (V 1.0)
17
The EF2800 system is housed in a 4 × 4 enclosure, i.e. 4 bays wide by
4 bays high. The front bays are numbered 1 to 4 from left to right, when
viewed from the front, and 1 to 4 from top to bottom. Drive Carrier
Module locations are identified from a matrix of the top and side
numbers. The rear bays are numbered 1 to 5 from right to left, when
viewed from the rear. Module locations are identified by a matrix of the
top and side numbers.
NOTE :
For proper operation of SES (SCSI Enclosure Services), drive
module must always be installed in bays 1/1 (drive 0) and 4/4 (drive 15).
2.2 Rack-Mounting the Enclosure
2.2.1 Pre-Requisites
The EF2800 enclosure is designed for installation into an industry
standard 19-inch cabinet capable of holding the unit.
• Minimum depth 20.12" (511mm) from front flange to rear
metalwork (excludes rear cabling)
PSU/Cooling 1
Storage
Storage
Ops Panel
PSU/Cooling 2
Manager A
Manager B
Figure 15. Module Locations at Rear
12345
Ensure that you have checked and fitted a suitable anti-
static wrist or ankle strap and observe all conventional
ESD precautions when handling EF2800 modules and
components. Avoid contact with backplane components
and module connectors.
!
Warning
Comentários a estes Manuais