Troubleshooting and Problem Solving
DataDirect Networks EF2800 FC RAID Storage System User Guide (V 1.0)
147
10.2.3 Power Supply/Cooling Module
The Power Supply Cooling LEDs are shown in Figure 65. Under Normal
conditions the LEDs should all be illuminated constant green. If a
problem is detected the color of the relevant LED will change to amber.
10.3 Audible Alarm
The Ops Panel also includes an audible alarm which indicates when a
fault state is present. The following conditions will activate the audible
alarm:
•Drive Fault
•Fan Fault
Voltage out of range
Over temperature
Thermal overrun
System fault
10.3.1 Audible Alarm Mute
When the audible alarm sounds, it may be muted by pressing the Alarm
Mute push-button. Automatic muting will take place after two minutes
if the mute switch is not manually operated. The Alarm Mute push-
button is located above the indicators on the Ops Panel
(Figure 61).
When the alarm is muted it will continue to sound with short
intermittent beeps to indicate that a problem still exists. It will be
silenced when all problems are cleared.
10.3.2 LED Test Mode
The Alarm Mute push-button can also be used to test the LEDs on the
Ops Panel. When the Mute push-button is held, all LEDs will be
illuminated if there are no faults present.
Power AC Fan DC Output
PSU Good: Green
AC Input Fail: Amber
Fan Fault: Amber
DC Output Fail: Amber
Figure 65. PSU LEDs