142
DataDirect Networks EF2800 FC RAID Storage System User Guide (V 1.0)
Troubleshooting and Problem Solving
10.1.1.2 Alarm Sounds On Power Up
Please refer to Section 10.3.
10.1.1.3 Green “Signal Good” LED on I/O Module is Off
Check that the Rx and Tx cables have not been inverted during
installation.
10.1.1.4 Computer Doesn’t Recognize the EF2800 System
1. Check that the FC-AL interface cables from the EF2800 enclosure
to the host computer are fitted correctly.
2. Check the Drive Select ID settings on your EF2800 enclosure and
on your system host.
3. Check that the LEDs on all installed drive carrier modules are
illuminated green. Note that the drive LEDs will not be lit during
drive spinup.
4. Check that all drive carrier modules have been correctly installed.
5. Check that there is a valid FC-AL signal present at the I/O
connector. If there is no signal present check that the cable has
not been inverted during installation.
6. Check the I/O module setup as follows:
- Check that the I/O module has been correctly installed and all
external links and cables are securely fitted.
- Check the maximum cable length has not been exceeded.
Comentários a estes Manuais