DataDirect EF2800 Guia do Utilizador Página 188

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 187
Troubleshooting and Problem Solving
DataDirect Networks EF2800 FC RAID Storage System User Guide (V 1.0)
165
10.14 Warning and Error Events
There are a number of conditions that trigger warning or error events,
activate the alarm, and may affect the state of the Status and Fault
LEDs. The alarm or buzzer sounds mainly when SAM or the Disk Array
Administrator displays a warning or error event.
The alarm will silence when you press the Mute button on the EF2800,
mute the alarm in SAM (refer to Section 8.5, "Changing the Alarm Mute
Setting" on page 122) or acknowledge the event by pressing <Esc> in
the Disk Array Administrator. The events in these categories are listed
below.
10.14.1 Warnings
Warning events let you know that something related to the EF2800 or
an array has a problem. You should correct the problem as soon as
possible. Figure 70 defines each warning event and recommends the
action you should take.
Figure 70. Warning Events
Event Definition Recommended Action
ARRAY
CRITICAL
One or more drives are down
and the array is online, but is
no longer fault tolerant.
Add a spare to the array or the spare
pool. Then replace the bad drives.
Refer to Section
5.4..
ARRAY
OFFLINE
More than one drive in a RAID
0 or volume set went down
bringing the array to an
offline state. This array is no
longer accessible by the host.
Replace the bad drive and restore
the data from backup.
BATT FAIL
INFO
A warning condition in the
battery pack or charging
interface has been detected.
Contact Customer Service for
battery replacement.
Vista de página 187