162
DataDirect Networks EF2800 FC RAID Storage System User Guide (V 1.0)
Troubleshooting and Problem Solving
To change the backoff percentage using Disk Array Administrator:
A change to this setting on either SM module is automatically updated
on the other SM module.
1. From the System Menu, select Configuration Menu and press
<Enter>. The Configuration Menu displays.
2. Select Backoff Percent and press <Enter>. The Backoff Percent
screen displays.
3. Enter the Backoff Percent you want to use and press <Enter>.
Enter the percentage as three digits using the following format:
00.0%. The default setting is 01.0%.
10.11 EF2800 Problems
Problem: The Storage Manager module’s Status LED does not turn on.
Check that the SM module is properly seated in the slot and the
handles are closed and locked. Check for events in SAM and the RS-
232 interface (Disk Array Administrator) for power-on initialization
and diagnostics errors.
Problem: The EF2800
reports an SDRAM memory error.
Contact Technical Support.
10.12 Problems During Startup (when using Disk Array
Administrator)
The following sections describe problems you might encounter when
using the Disk Array Administrator during Power On Self-Test (POST)
or during startup and explain how to resolve those problems. POST
shows problems related to the processor, logic, and memory.
Problem: EF2800
failed the onboard memory test.
When this failure occurs, it means the internal CPU memory failed.
Contact Technical Support for a replacement.
Vista de página 184