300
DataDirect Networks EF2800 FC RAID Storage System User Guide (V 1.0)
Configuring the EF2800
To shut down the other SM module:
1. From the System Menu, select Shutdown Menu and press <Enter>.
The Shutdown Menu displays.
2. Select Shutdown Other and press <Enter>.
3. The system prompts you to confirm shut down. Select Yes and
press <Enter>. The system confirms that it has shut down.
H.1.3 Shutting Down Both SM Modules
You can simultaneously and gracefully shut down both SM modules.
Use this in preparation to power down the whole system for
maintenance, repair, or a move.
C
AUTION
!
Shutting down both SMs will cause users to lose access to
data and will interrupt the flow of data.
To shut down both SM modules:
1. From the System Menu, select Shutdown Menu and press
<Enter>. The Shutdown Menu displays.
2. Select Shutdown Both and press <Enter>.
3. The system prompts you to confirm shut down. Select Yes and
press <Enter>. Both SMs shut down.
4. To restart both SM modules, press <Enter> at the same time on
both SM modules.
H.1.4 Other Controller Menu
In addition to the previous shutdown menu, "other controller menu"
gives the ability to kill or unkill the other SM module, as well as shut
down the other or both SM modules.
C
AUTION
!
If the SM module is the only one working of the redundant
pair, then killing the other SM module will cause users to lose access to
data and will interrupt the flow of data.